Non-numbered addresses

The following table lists the details of the Non-numbered Address parameters.

Parameter Also known as point parameter. A unit of information about a point. For example, an analog point includes parameters such as process variable parameter (PV), output parameter (OP) and setpoint parameter (SP). See also: analog point, output parameter, point, process variable, setpoint parameter. Address Line Param Format Access Devices

Relay #1

RELAY1

Discrete (bits).

[Status Point A type of standard point that is used to represent discrete or digital field values. See also: dual-bit status point, standard point. Only]

RO

DR4300

Relay #2

RELAY2

Discrete (bits).

[Status Point Only]

RO

DR4300

Alarm An indication (visual and/or audible) that alerts an operator at a Station of an abnormal or critical condition. Each alarm has a type and a priority. Alarms can be assigned either to individual points or for system-wide conditions, such as a controller communications failure. Alarms can be viewed on a Station display and included in reports. Experion classifies alarms into the following types: - PV Limit - Unreasonable High and Unreasonable Low - Control Failure - External Change. Relay #1

ALMRLY1

Discrete (bits).

[Status Point Only]

RO

DR4500

Alarm Relay #2

ALMRLY2

Discrete (bits).

[Status Point Only]

RO

DR4500

Control Relay #1

CR1

Discrete (bits).

[Status Point Only]

RO

DR4500

Control Relay #2

CR2

Discrete (bits).

[Status Point Only]

RO

DR4500

Control Relay #3

CR3

Discrete (bits).

[Status Point Only]

RO

DR4500

Control Relay #4

CR4

Discrete (bits).

[Status Point Only]

RO

DR4500

Control Relay

CR

Discrete (bits).

[Status Point Only]

RO

UDC2300, UDC3300

Alarm Relay #2

ALMRLY2

Discrete (bits).

[Status Point Only]

RO

UDC2300, UDC3300

Alarm Relay #1

ALMRLY1

Discrete (bits).

[Status Point Only]

RO

UDC2300, UDC3300

INSTMODE

INSTMODE

Floating Point

RW

UMC800, HC900 Hybrid controller.

CONFIG_CLEAR

CONFIG_CLEAR

Floating Point

WO

HC900

LOAD_RECIPE

LOAD_RECIPE

Floating Point

WO

UMC800

CHART_SPEED

CHART_SPEED

Floating Point

RO

DR4300, DR4500

Pen #1 High Value

PEN1HI

Floating Point

RO

DR4300, DR4500

Pen #1 Low Value

PEN1LO

Floating Point

RO

DR4300, DR4500

Number of Chart Divisions

CHART_DIVS

Floating Point

RO

DR4500

CHART_STATUS

CHART_STATUS

Floating Point

RO

DR4500

Pen #1 Status

PEN1STAT

Floating Point

RO

DR4500

Pen #2 Status

PEN2STAT

Floating Point

RO

DR4500

Pen #2 High Value

PEN2HI

Floating Point

RO

DR4500

Pen #2 Low Value

PEN2LO

Floating Point

RO

DR4500

Pen #3 Status

PEN3STAT

Floating Point

RO

DR4500

Pen #3 High Value

PEN3HI

Floating Point

RO

DR4500

Pen #3 Low Value

PEN3LO

Floating Point

RO

DR4500

Pen #4 Status

PEN4STAT

Floating Point

RO

DR4500

Pen #4 High Value

PEN4_HIGH

Floating Point

RO

DR4500

Pen #4 Low Value

PEN4_LOW

Floating Point

RO

DR4500